Yuchen WaterYuchen Water
Selected performance evidence

Activated Carbon Filter Performance Test Data

Review selected result tables for individual activated carbon and carbon block filter samples. Capacities, conditions, units and reporting limits remain visible so technical buyers can evaluate exactly what each excerpt demonstrates.

Test data overview

Use this summary to identify a relevant test topic before opening the watermarked source excerpt.

Test topicTest capacityConditions / compoundsSelected result
Lead reduction data at pH 8.5≤ 400 gallonspH 8.5 · 135–165 µg/L≤5 µg/L · later checkpoints <1 µg/L
Mercury reduction data at pH 8.5≤ 400 gallonspH 8.577.05%–85.51%
Emerging compounds data - Group 1≤ 500 gallonsMeprobamate · Atenolol · Carbamazepine · DEETPassed at every listed checkpoint
Emerging compounds data - Group 2≤ 500 gallonsTCEP · TCPPPassed at every listed checkpoint
Emerging compounds data - Group 3≤ 500 gallonsPhenytoin · Ibuprofen · NaproxenPassed at every listed checkpoint
Chloramine reduction data≤ 900 gallonsTwo tested samples92.73%–99.70%
PFOA and PFOS reduction data≤ 504 gallonsPFOA · PFOS · two tested samplesPassed at every listed checkpoint
Cyst-surrogate reduction dataMicrospheres used as a cyst surrogate99.97%–99.99%
Selected excerpt

Lead reduction data at pH 8.5

Test capacity
≤ 400 gallons
Conditions / compounds
pH 8.5 · 135–165 µg/L
Selected result
≤5 µg/L · later checkpoints <1 µg/L
Reporting or detection limit
1 µg/L
Selected excerpt

Mercury reduction data at pH 8.5

Test capacity
≤ 400 gallons
Conditions / compounds
pH 8.5
Selected result
77.05%–85.51%
Reporting or detection limit
0.1 µg/L
Selected excerpt

Emerging compounds data - Group 1

Test capacity
≤ 500 gallons
Conditions / compounds
Meprobamate · Atenolol · Carbamazepine · DEET
Selected result
Passed at every listed checkpoint
Reporting or detection limit
1–10 ng/L
Selected excerpt

Emerging compounds data - Group 2

Test capacity
≤ 500 gallons
Conditions / compounds
TCEP · TCPP
Selected result
Passed at every listed checkpoint
Reporting or detection limit
10 ng/L
Selected excerpt

Emerging compounds data - Group 3

Test capacity
≤ 500 gallons
Conditions / compounds
Phenytoin · Ibuprofen · Naproxen
Selected result
Passed at every listed checkpoint
Reporting or detection limit
1–10 ng/L
Selected excerpt

Chloramine reduction data

Test capacity
≤ 900 gallons
Conditions / compounds
Two tested samples
Selected result
92.73%–99.70%
Reporting or detection limit
0.01 mg/L
Selected excerpt

PFOA and PFOS reduction data

Test capacity
≤ 504 gallons
Conditions / compounds
PFOA · PFOS · two tested samples
Selected result
Passed at every listed checkpoint
Reporting or detection limit
0.001 µg/L
Selected excerpt

Cyst-surrogate reduction data

Test capacity
Conditions / compounds
Microspheres used as a cyst surrogate
Selected result
99.97%–99.99%
Reporting or detection limit
Important scope

Results apply only to the tested samples, conditions and dates stated in the supporting records. This page does not represent NSF certification, NSF listing or automatic performance of every filter in our range.

How buyers should interpret the data

  • Match the tested sample construction, dimensions and media to the product under evaluation.
  • Compare flow, capacity, challenge-water conditions and system configuration before using a result in a purchasing decision.
  • A laboratory test report is not the same as product certification or listing.
  • Supporting documents are released only after email verification and manual business review.

Buyer questions about the test data

Are these carbon filters NSF certified?

No certification or listing is claimed on this page. The excerpts reproduce selected results for specific tested samples and conditions.

Which filter models do these results apply to?

Applicability must be confirmed against the tested sample, media, dimensions, flow and system configuration. A result must not be applied automatically to the whole product range.

Can distributors request supporting documentation?

Yes. Complete the protected request, verify your email and provide enough project information for a manual business review.

What should an OEM buyer provide?

Provide the intended cartridge type, size, media, target flow, market, expected quantity and the claim or evaluation requirement you need to support.

Request supporting documentation

Request supporting test documentation

Submitting the form does not release a file. Verify your email first; our team then reviews the company, intended use and requested evidence.

  1. Complete every required business field.
  2. Verify your email using the private link.
  3. Wait for manual review and approval.
  4. Approved files receive customer-specific watermarks and a limited-time link.
Requested test topics

Selected test data

Selected test data

Selected excerpt only. Repeated Yuchen Water watermarks protect the source while preserving values, units and table relationships.